Please use this identifier to cite or link to this item: https://repository.uniminuto.edu/handle/10656/18723
Title: Evaluación del Sistema de Captación de Agua Lluvia implementado en un proyecto de Construcción.
Authors: Molina Gómez, Carolina
Ortiz López, Pablo Augusto
metadata.dc.contributor.advisor: Duque, Olga Lucia
Keywords: Aguas lluvias
aprovechamiento
Consumo de agua
Sistema de captación
Baterías sanitarias
Publisher: Corporación Universitaria Minuto de Dios - UNIMINUTO
Citation: Molina, C., y Ortiz, P.(2023). Evaluación del Sistema de Captación de Agua Lluvia implementado en un proyecto de Construcción(Trabajo de grado/Tesis Especialización). Corporación Universitaria Minuto de Dios - UNIMINUTO. Chinchiná – Colombia.
Abstract: El presente proyecto investigativo busca evaluar y verificar el correcto funcionamiento del sistema de captación de aguas lluvias, implementado en el proyecto de construcción Icarú que se está desarrollando en el sector de bosques de Niza de la ciudad de Manizales, con el propósito de identificar si el agua captada es suficiente para abastecer la batería sanitaria y reflejar la disminución del consumo de agua potable del acueducto de la región. Utilizando el tipo de investigación cuantitativo de carácter no experimental tomando datos en campo del consumo del recurso hídrico generado por parte de los colaboradores, comparado con los datos de la cantidad de pluviosidad registrada por una de las estaciones del IDEAM adyacente al sector de construcción la cual es la estación meteorológica Tesorito La Finca. Se realizó el análisis de la información suministrada por el IDEAM en cuanto al reporte de las precipitaciones mensuales registradas, se determinó la cantidad de agua consumida por la batería sanitaria en función de los ingresos por parte del personal administrativo de la construcción en proceso, se verificaron las fichas técnicas de los elementos que componen el sistema, matrices de datos, tabulación de información y ecuaciones matemáticas, brindando como resultado la identificación de los niveles óptimos de captación de aguas lluvias para suplir la demanda de consumo de los colaboradores, identificar la cantidad de pluviosidad del sector y el porcentaje de agua aprovechada por un servicio sanitario reflejando la disminución del consumo de agua potable por parte del proyecto de construcción. ODS?
This research project seeks to evaluate and verify the proper functioning of the rainwater harvesting system, implemented in the Icarú construction project that is being developed in the Niza forest sector of the city of Manizales, with the purpose of identifying if the The collected water is enough to supply the sanitary battery and reflect the decrease in the consumption of drinking water from the aqueduct in the region. Using the type of quantitative research of a non-experimental nature, taking data in the field on the consumption of the water resource generated by the collaborators, compared with the data on the amount of rainfall recorded by one of the IDEAM stations adjacent to the construction sector, which is the Tesorito La Finca weather station. The analysis of the information provided by the IDEAM was carried out regarding the report of the registered monthly precipitations, the amount of water consumed by the sanitary battery was determined based on the income by the administrative personnel of the construction in process, they were verified the technical sheets of the elements that make up the system, data matrices, tabulation of information and mathematical equations, providing as a result the identification of the optimal levels of rainwater collection to meet the consumption demand of collaborators, identify the amount of rainfall in the sector and the percentage of water used by a sanitary service, reflecting the decrease in drinking water consumption by the construction project.
Description: El objetivo general de este estudio radica en la evaluación de la eficiencia y efectividad del sistema de captación de agua lluvia implementada en el proyecto de construcción Icarú, con una atención especial en su capacidad para proveer de agua a las baterías sanitarias y así reducir la demanda de agua potable. La justificación de este estudio encuentra sus fundamentos en la coherencia con los Objetivos de Desarrollo Sostenible (ODS), especialmente el ODS 6 (Agua limpia y saneamiento), cuyo objetivo es garantizar que el agua sea accesible para todos y se gestione de manera sostenible. También tiene como objetivo contribuir a las medidas de ordenamiento territorial del país y la gestión eficaz de los recursos hídricos, según lo estipulado en el Plan Nacional de Desarrollo 2022-2026.
URI: https://repository.uniminuto.edu/handle/10656/18723
Appears in Collections:Especialización en Gerencia de Proyectos

Files in This Item:
File Description SizeFormat 
Aguas residuales.pdf16.89 MBAdobe PDFView/Open
Autorización Aguas Residuales.pdf
  Restricted Access
278.37 kBAdobe PDFView/Open Request a copy


This item is licensed under a Creative Commons License Creative Commons