Please use this identifier to cite or link to this item: https://repository.uniminuto.edu/handle/10656/13627
Title: Evaluación de vulnerabilidad sísmica y estructural de las instalaciones del antiguo Instituto Técnico Universitario de Cundinamarca (ITUC) en el Municipio de Girardot.
Authors: Chavez Garcia, Camila Andrea
Herrera Bautista, Lina Maria
Rodriguez Villanueva, Michael Steven
metadata.dc.contributor.advisor: Gulfo Mendoza, Aldemaro Manuel
Keywords: Sistema estructura
Vulnerabilidad sísmica
Vulnerabilidad estructural
Edificación
Construcción
Mampostería
Publisher: Corporación Universitaria Minuto de Dios
Citation: Chavez,C.,Herrera.L. y Rodriguez,M.(2020).Evaluación de vulnerabilidad sísmica y estructural de las instalaciones del antiguo Instituto Técnico Universitario de Cundinamarca (ITUC) en el Municipio de Girardot..(Trabajo de grado).Corporación Universitaria Minuto de Dios.Girardot-Colombia
Abstract: La presente investigación se llevara a cabo un estudio vulnerabilidad sísmica y estructural de las instalaciones del antiguo ITUC (instituto técnico universitario de Cundinamarca), se evaluara el riego sísmico de estas instalaciones y el grado de daño estructural que presentan hasta el día de hoy, teniendo en cuenta que estas instalaciones fueron construidas en el año 1902, por lo tanto son estructuras antiguas que no contaron con un parámetro reglamentario para la construcción de estas instalaciones Para evaluar esta investigación se llevaron a cabo una serie de procedimientos como: inspección visual, levantamientos arquitectónicos, topográficos, estudio de suelos y apiques. Con los cuales se pudo determinar que estas instalaciones cuentan con un sistema estructural de muros portantes (muros de carga). Basándose en los estudios realizados no se encontró ningún tipo de refuerzo continuo o persistente en las diferentes estructuras. Por lo tanto, se procederá a llegar a conclusiones o recomendaciones más exactas, con el fin de garantizar que estas estructuras sean óptimas para su uso y función, en caso de que se presenten movimientos telúricos. Teniendo en cuenta los requisitos básicos de diseño y construcción que presenta la norma sismo resistente (nsr10).
In the present investigation a seismic and structural vulnerability study of the facilities of the former ITUC (university technical institute of Cundinamarca) will be carried out. The seismic irrigation of these facilities and the degree of structural damage that they present until today will be evaluated, taking into account that these facilities were built in 1902, therefore they are old structures that did not have a regulatory parameter for the construction of these facilities. To evaluate this research, a series of procedures were carried out, such as: visual inspection, architectural and topographic surveys, soil and excavation studies. With which it was determined that these facilities have a structural system of bearing walls (load-bearing walls). Based on the studies carried out, no continuous or persistent reinforcement was found in the different structures. Therefore, more accurate conclusions or recommendations will be reached, in order to ensure that these structures are optimal for their use and function, in case of telluric movements taking into account the basic design and construction requirements presented by the earthquake resistant standard (NSR-10).
Description: Determinar el grado de vulnerabilidad sísmica y estructural de las instalaciones del instituto técnico universitario de Cundinamarca (ITUC) ubicado en el municipio de Girardot, Cundinamarca.
URI: https://hdl.handle.net/10656/13627
Appears in Collections:Ingeniería Civil

Files in This Item:
File Description SizeFormat 
autorizacion_ChavezCamila_HerreraLina-RodriguezMichael_2019.pdf
  Restricted Access
Autorización50.16 kBAdobe PDFView/Open Request a copy
T.IC_ChavezCamila_HerreraLina_RodriguezMichael_2019.pdfDocumento Principal3.16 MBAdobe PDFView/Open