Please use this identifier to cite or link to this item: https://repository.uniminuto.edu/handle/10656/12218
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCardenas Castellanos , Luis Miguel
dc.contributor.authorCastro Corredor, Angie
dc.contributor.authorAldana Pantoja, Maria de los Angeles
dc.contributor.authorGarcia Betancourt, Johanna Katherine
dc.coverage.spatialGirardot (Cundinamarca)spa
dc.date.accessioned2021-06-09T18:32:40Z
dc.date.available2021-06-09T18:32:40Z
dc.date.issued2020-12-11
dc.identifier.citationCastro,A.,Aldana,M. y Garcia,J.(2020).Evaluación de la iluminación y percepción del confort en los trabajadores de urgencias del hospital Louis Pasteur de Melgar Tolima en el 2019-2020,(Trabajo de grado).Corporación Universitaria Minuto de Dios.Girardot-Colombiaspa
dc.identifier.urihttps://hdl.handle.net/10656/12218
dc.descriptionEvaluar la iluminación en los diferentes puestos de trabajos administrativos de la central de urgencias del hospital, mediante el equipo de medición, el luxómetro en el 2019-2020spa
dc.description.abstractLa presente investigación se refiere al tema de iluminación en los puestos de trabajo de la central de urgencias Louis Pasteur de melgar Tolima, 2019-2020 donde no cuenta con un estudio formal que permita conocer el estado del sistema de iluminación de la infraestructura, para dicho estudio tomaremos como referencia Reglamento Técnico de Iluminación y Alumbrado Público (RETILAP). Además, se analizará la percepción de confort de los trabajadores, los cuales están expuestos al factor de riesgo de iluminación en el trabajo, debido a una iluminación incorrecta, por exceso o defecto, que puede acarrear patologías asociadas como dolores de cabeza, irritación de los ojos, y cansancio ocular, entre otros, todo esto son factores que puedan causar accidentes, ausentismo laboral y bajo rendimiento. Siendo esta la razón por la que se decide hacer el estudio de iluminación, para identificar en qué estado se encuentra la iluminación de las oficinas administrativas de la parte antigua de la central de urgencias, si están acordes al reglamento RETILAP, o si por el contrario habrá que hacer mejoras en el sistema de iluminación en la central de urgencias Louis Pasteur. El objetivo de esta investigación es diseñar estrategias para mejorar la iluminación en los puestos administrativos de la central de urgencias del hospital Louis Pasteur de Melgar – Tolima, del mismo modo realizar las mediciones de los niveles de iluminación de cada puesto de trabajo administrativo durante diferentes horas del día; Además diseñar estrategias para mitigar enfermedades laborales por iluminación inadecuada y por ultimo evaluar el riesgo para determinar los controles en los puestos de trabajo, resultado de la medición de iluminación y análisis realizado. Para realizar esta investigación se tuvo en cuenta el RETILAP (Reglamento técnico de iluminación y alumbrado público, a partir del 1 de abril de 2010 empezó a regir en Colombia). Por otra parte, el diagnóstico de la iluminación se pretende llevar acabo por medio de una investigación descriptiva y observacional, se apoya con instrumentos de medición como test de iluminación y un cuestionario de evaluación subjetiva, con la que se pretende recoger su opinión sobre condiciones de iluminación en los puestos de trabajo. Como primer paso se deben obtener los planos arquitectónicos de las instalaciones físicas de la central de urgencias Louis Pasteur de Melgar - Tolima, conseguir el equipo de iluminación (luxómetro), posteriormente se diseñan formatos para registrar las medidas según el RETILAP, que define realizar seis medidas diferentes en iluminación interior, de diferentes aulas, los resultados obtenidos se graficarán y se analizarán de manera individual y grupal, esto con el fin de identificar los puestos de trabajo que no cumplen con los niveles mínimos de iluminancia, luego se establecerá la presencia de condiciones inseguras en algunos puestos de trabajo como son los soportes de luminarias, se evidenciará los puestos de trabajo con falencia de luz natural. Teniendo en cuenta las mediciones con el LUXOMETRO y el rango arrojado en cada puesto de trabajo, se procede a comparar los valores obtenidos con el RTILAP, y se observó que no cumplen con los límites establecidos por la norma, por otra parte se presentaron encuestas, descriptivas y obvencionales test de iluminación y un cuestionario de evaluación subjetiva, al personal, donde se vio reflejado las molestias que les causa en la salud por el déficit de iluminación en cada puestos de trabajo. Con la investigación realizada se puede concluir, que las oficinas administrativas de la parte antigua de la central de Urgencias Louis Pasteur, no cuentan con buena iluminación y además carece de ventanas, algunas luminarias no se encuentran en buen estado, la ubicación de los escritorios no están bien ubicados y cuando hace sol los rayos pegan contra la pared ocasionando brillo al computador haciendo que le afecte la visión. Todo esto conlleva a que los funcionarios tengan bajo rendimiento laboral y que su salud desmejore.spa
dc.description.abstractThis research refers to the topic of lighting in the work stations of the Louis Pasteur de Melgar Tolima emergency center, 2019-2020 where there is no formal study that allows knowing the status of the infrastructure lighting system, for said This study will take as a reference Technical Regulation for Public Lighting and Lighting (RETILAP). In addition, the perception of comfort of the workers will be analyzed, who are exposed to the risk factor of lighting at work, due to incorrect lighting, excess or defect, which can lead to associated pathologies such as headaches, eye irritation, and eye strain, among others, all these are factors that can cause accidents, absenteeism and poor performance. This being the reason why it is decided to do the lighting study, to identify the state of the lighting in the administrative offices of the old part of the emergency center, if they are in accordance with the RETILAP regulation, or if on the contrary Improvements will have to be made to the lighting system at the Louis Pasteur emergency room. The objective of this research is to design strategies to improve lighting in the administrative posts of the emergency center of the Louis Pasteur hospital in Melgar - Tolima, in the same way to measure the lighting levels of each administrative job during different hours. of the day; In addition, designing strategies to mitigate occupational illnesses due to inadequate lighting and finally assessing the risk to determine the controls in the jobs, the result of the lighting measurement and analysis carried out. To carry out this research, the RETILAP was taken into account (technical regulation for lighting and public lighting, as of April 1, 2010, it became effective in Colombia). On the other hand, the lighting diagnosis is intended to be carried out by means of a descriptive and observational research, it is supported by measurement instruments such as a lighting test and a subjective evaluation questionnaire, with which it is intended to collect your opinion on lighting conditions in jobs. As a first step, the architectural plans of the physical facilities of the Louis Pasteur de Melgar - Tolima emergency center must be obtained, obtaining the lighting equipment (lux meter), then formats are designed to record the measurements according to RETILAP, which defines performing six different measures in interior lighting, of different classrooms, the results obtained will be plotted and analyzed individually and in groups, this in order to identify the jobs that do not meet the minimum levels of illuminance, then the presence of unsafe conditions in some workstations such as light fixtures, workstations with lack of natural light will be evident. Taking into account the measurements with the LUXOMETER and the range found in each job, we proceed to compare the values obtained with the RTILAP, and it was observed that they do not comply with the limits established by the standard, on the other hand, surveys were presented, descriptive and obventional lighting test and a subjective evaluation questionnaire for the staff, where the discomfort caused to their health by the lighting deficit in each of the jobs was reflected. With the investigation carried out, it can be concluded that the administrative offices of the old part of the Louis Pasteur Emergency Center do not have good lighting and also lack windows, some lights are not in good condition, the location of the desks is not They are well located and when it is sunny the rays hit the wall causing the computer to shine, affecting its vision. All this leads to officials having poor work performance and their health deteriorating.eng
dc.format.extent71 Paginasspa
dc.format.mimetypeapplication/pdf
dc.language.isospaspa
dc.publisherCorporación Universitaria Minuto de Diosspa
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.subjectConfortspa
dc.subjectIluminaciónspa
dc.subjectMedio Ambientespa
dc.subjectSustentabilidadspa
dc.subjectSeguridad y salud en el trabajospa
dc.titleEvaluación de la iluminación y percepción del confort en los trabajadores de urgencias del hospital Louis Pasteur de Melgar Tolima en el 2019-2020spa
dc.typeThesiseng
dc.subject.keywordsComforteng
dc.subject.keywordsLighting Environmenteng
dc.subject.keywordsSustainabilityeng
dc.subject.keywordsSafety and health at workeng
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2
dc.rights.accessrightsinfo:eu-repo/semantics/openAcces
dc.rights.licenseEL AUTOR, manifiesta que la obra objeto de la presenta autorización es original y la realizo sin violar o usurpar derechos de autor de terceros, por lo tanto, la obra es de exclusiva autoría y tiene la titularidad sobre la misma. PARAGRAFO: En caso de presentarse cualquier reclamación o acción por parte de un tercero en cuanto a los derechos de autor sobre la obra en cuestión, EL AUTOR, asumirá toda la responsabilidad, y saldrá en defensa de los derechos aquí autorizados; para todos los efectos la universidad actúa como un tercero de buena fe. EL AUTOR, autoriza a LA CORPORACIÓN UNIVERSITARIA MINUTO DE DIOS, para que los términos establecidos en la Ley 1581 de 2012 en el artículo 30 de la Ley 23 de 1982 y el artículo 11 de la Decisión Andina 351 de 1993 y toda normal sobre la materia, utilice y use la obra objeto de la presente autorización. TRATAMIENTO DE DATOS PERSONALES, EL AUTOR declara y autoriza lo dispuesto en el Articulo 10 del Decreto 1377 de 2013 a proceder con el tratamiento de los datos personales para fines académicos, históricos, estadísticos y administrativos de la Institución. De conformidad con lo establecido, aclaramos que “Los derechos morales sobre el trabajo son propiedad de los autores”, los cuales son irrenunciables, imprescriptibles, inembargables e inalienables.spa
dcterms.bibliographicCitation(INSHT), E. I. (2016). Ivassat. Obtenido de Ivassat: http://www.invassat.gva.es/en/visor-biblioteca/-/asset_publisher/LvSYKI0K6pLa/content/espana-instituto-nacional-de-seguridad-e-higiene-en-el-trabajo-insht-2014-carta-de-servicios-2015-2018;jsessionid=5F86525FED4E3EB196A39EFB7A96103E
dcterms.bibliographicCitationEnergya. (19 de 3 de 2009). Obtenido de https://www.energyavm.es/quien-fue-el-inventor-de-la-luz-electrica/#:~:text=El%20inventor%20%C2%ABoficial%C2%BB%20de%20la,una%20bombilla%20incandescente%20con%2
dcterms.bibliographicCitationGonzales, A. M. (2015). INFLUENCIA DEL ALUMBRADO PUBLICO SOBRE LA SEGURIDAD Y LA CONDUCTA
dcterms.bibliographicCitationIDAE. (03 de 2001). “Guía Técnica de Eficiencia Energética en Iluminación. Hospitales y Centros de. Obtenido de https://www.idae.es/uploads/documentos/documentos_5573_GT_iluminacion_hospitales_01_81a4cdee.pdf
dcterms.bibliographicCitationPalermo, U. d. (1 de 6 de 2017). que es la iluminacion. Recuperado el 21 de 09 de 2020, de http://fido.palermo.edu/servicios_dyc/blog/alumnos/trabajos/13496_12833.pdf
dcterms.bibliographicCitationPattinni. (20020). LA LUZ NATTURAL E ILUMINACION DE INTERIORES . Obtenido de http://www.edutecne.utn.edu.ar/eli-iluminacion/cap11.pdf
dcterms.bibliographicCitationSoto, L. D. (26 de 11 de 2009). Radiaciones electromagnéticas y salud en la investigación médica. Obtenido de http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0138-65572010000100005
dcterms.bibliographicCitationTorres, H. M. (30 de 03 de 2010). MINISTRO DE MINAS Y ENERGIA. Obtenido de file:///C:/Users/Angie/Downloads/RETILAP.pdf
dc.publisher.departmentPregrado (Virtual y a Distancia)spa
dc.publisher.programAdministración en Salud Ocupacionalspa
dc.type.spaMonografíaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_46ec
dc.rights.localOpen Access
dc.identifier.instnameinstname:Corporación Universitaria Minuto de Dios
dc.identifier.reponamereponame:Colecciones Digitales Uniminuto
dc.identifier.repourlrepourl:https:// repository.uniminuto.edu
Appears in Collections:Administración en Salud Ocupacional

Files in This Item:
File Description SizeFormat 
UVDT.SST_CastroAngie-AldanaMaria-GaciaJohanna_2020.pdfDocumento Principal1.09 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons